Methods of operation:
1, Clear out code:
To Clear up test stored rf signal memory from factory by pressing the locking key and unlock the key at the same time, two seconds later, LED indicator light flashes three times, followed by a continuous fast blinking. Indicates that the remote control codes stored has been cleared out.
2, Duplicating (learning)
Hands are holding remote control , and the other are holding the duplicating remote control, 2 remote controls put together as close as possible, while pressing the remote controls two match button,(eg: A-A’,B-B’) three seconds later, LED indicator light flashes three times, followed by a continuous fast blinking. This indicates that this copy of the remote control buttons are same as copied on the remote control button codes . Several other keys are also according to the above approach to learning.
3, Recovery code
If the code copied have been mistakenly removed the remote control, you do not worry, the remote control can restore yourself. Method is pressing (up-down eg: locking key and bell key) two buttons (metal shell remote control on the left, the plastic shell remote control on the right) at the same time ,3 seconds later, LED indicator light flashes three times, followed by a continuous fast blinking. This indicates that the original remote control codes have been restored.
4.The other way, you can delete all and relearn them again.
Receiver:
Usage :
Controller using microprocessor intelligent control ,can be used in Garage door control, Lighting Control,Remote curtain etc .with Easy installation and simple to use , Safe and reliable features .
Technology Parameter:
1. Working Volt :12V / 24V
2. Memory: 30 (learning code )
3. Operating temp: -40°C - +80°C
4. Working frequency: 315 MHz / 433MHz
5. Sensitivity: ≥-105dBm
6. Output current: ≤10A
7. Control voltage: AC/DC